top of page

TEMPERATURE-HUMIDITY-GAS MEASUREMENT SYSTEMS

Temperature-Humidity Transmitters

sıcaklık nem olcum4

It is NTC temperature sensor transmitter with HD01-AN Display. Thanks to the NTC sensors on it, this information is transferred to the outside world by measuring the temperature.

Due to the nature of the NTC sensors, temperature measurements can be made according to the process by producing in various metal cases.

Sensors used in cooling and HVAC systems are provided with analog output and RS485 Modbus output. 4 sensor inputs can be made as input to the device. Temperature information taken from 4 points can be transferred to other systems.

Control can be done with the help of the relay on it. Thanks to its RS485 Modbus communication output, it also addresses remote monitoring systems.

GENERAL FEATURES:

• 4 NTC sensor inputs,
• 1 logic input,
• 1 semi universal analog output,
• 1 Relay output,
• 2 Modbus RTU RS485 communication ports,
• Ac / Dc supply facility,
• Adjustable measuring time, filter and response time,
• Warning and guidance in case of sensor failure,
• 2 4 digit 11mm display indicators,
• 2 4 digit 9mm display indicators,
NTC sensor input and reading feature,
• 1 relay forwarding feature connected to the sensors,

GENERAL FEATURES:

• Logic input routing feature,
• Operation of relays in desired measurement unit and control form,
• Working in heating / cooling / band on / band off / Timer forms,
• 1 independent Timer,
• Working with Timer in alarm situations,
• Current or Voltage output can be taken from a single point. It does not require any terminal changes,
• Current and Voltage output type is selected with jumper,
• Current and Voltage outputs can be scaled by the user outside of the standard values,
Relay routing can be done according to logic input,
• Optional audible warning option.

sıcaklık nem olcum3

HD01-NN Indicator NTC temperature sensor transmitter. Thanks to the NTC sensors on it, this information is transferred to the outside world by measuring the temperature.

Due to the nature of the NTC sensors, temperature measurements can be made according to the process by producing in various metal cases.

Sensors used in cooling and HVAC systems are provided with analog output and RS485 Modbus output. 4 sensor inputs can be made as input to the device. Temperature information from 4 points can be transferred to other systems.

Control can be done with the help of the relay on it. Thanks to its RS485 Modbus communication output, it also addresses remote monitoring systems.

GENERAL FEATURES:

  • 4 NTC sensor inputs,

  • 1 logic input,

  • 1 semi universal analog output,

  • 1 Relay output,

  • 2 Modbus RTU RS485 communication ports,

  • Ac / Dc supply possibility,

  • Adjustable measuring time, filter and response time,

  • Warning and guidance in case of sensor failure,

  • NTC sensor input and reading feature,

  • 1 relay forwarding feature connected to the sensors,

  • Logic input routing feature,

GENERAL FEATURES:

  • Operation of relays in desired measurement unit and control form,

  • Working in heating / cooling / band on / band off / Timer forms,

  • 1 independent Timer,

  • Working with Timer in alarm situations,

  • Current or Voltage can be output from a single point. It does not require any terminal changes.

  • Current and Voltage output type is selected with jumper,

  • Current and Voltage outputs can be scaled by the user outside of the standard values,

  • Relay routing can be done according to logic input,

  • Optional voice alert option.

sıcaklık nem olcum5

HD01-NT Indicator NTC temperature sensor transmitter. Thanks to the NTC sensors on it, this information is transferred to the outside world by measuring the temperature.

Due to the nature of the NTC sensors, temperature measurements can be made according to the process by producing in various metal cases.

The analog output and RS485 Modbus output of the sensors used mostly in cooling and HVAC systems are provided. 4 sensor inputs can be made as input to the device. Temperature information from 4 points can be transferred to other systems.

Control can be done with the help of the relay on it. Thanks to its RS485 Modbus communication output, it also addresses remote monitoring systems.

GENERAL FEATURES:

  • Logic input routing feature.

  • Operation of relays in desired measurement unit and control form.

  • Working in heating / cooling / band on / band off / Timer forms.

  • 1 independent Timer.

  • Working with Timer in case of alarm.

  • Current or Voltage can be output from a single point. It does not require any terminal changes.

sıcaklık nem olcum2

HD02 SERIES temperature humidity transmitters are the devices that measure the temperature and humidity values in the environment and output depending on this measurement, at the same time, they can operate certain devices with the help of relays and provide information using the communication channel for remote access.

Our transmitters have analog output and relay outputs on the same card. It has RS485 Modbus RTu protocol as communication output. HD02 device has 2 temperature humidity sensors and 1 external NTC sensor.

Temperature and humidity sensors can be extended optionally, the cable length of the 2nd sensor can be extended up to 400 meters since a new technology is used. Versatile temperature humidity measurement can be provided in such large-scale warehouses, cold-air rooms, greenhouses and other large centers. Autonomous control can be done with the help of Relays on the device. Relays can output any system active or passive according to the set set values.

GENERAL FEATURES:

  • 2 temperature humidity sensor inputs. (Optional can be increased.)

  • 1 NTC sensor input.

  • 1 logic input.

  • 2 Universal analog outputs. No mechanical modifications required.

  • 3 Relay outputs.

  • 1 Modbus RTU RS485 communication port.

  • 2 4 digit 20.4mm display indicators.

  • Ac / Dc supply possibility.

  • Adjustable measuring unit for temperature sensor ° C & F.

  • Temperature humidity and dew point measurement feature.

  • Adjustable measuring time, filter and response time.

  • Warning and guidance in case of sensor malfunction.

  • NTC sensor input and reading feature.

  • 3 relay forwarding features connected to the sensors.

  • Logic input routing feature.

GENERAL FEATURES:

  • Current or Voltage can be output from a single point. It does not require any terminal changes.

  • Current and Voltage output type can be adjusted from the menu.

  • Current and Voltage outputs can be scaled by the user outside of the standard values.

  • Insulated analog output structure.

  • Adjustable screen options, parameters can be displayed on the desired screen.

  • The automatic dot option automatically changes the point display to the measured values ​​according to the measured value.

  • Relay routing can be done according to logic input.

  • Optional voice alert option.

  • Optional sensor addition feature.

  • Working in heating / cooling / band on / band off / Timer forms

  • 3 independent Timers.

  • Working with Timer in case of alarm.

  • Universal analog output.

  • Operation of relays in desired measurement unit and control form.

GAS MEASUREMENT SYSTEMS

Gaz olcum cıhazı5

HD01-AC Indicator Carbon Dioxide (CO2) transmitter. It is used to determine the CO2 content in the environment and to transfer it to the outside world as digital information.

It gives the CO2 rate of our device as a digital output, as well as it displays it to the users thanks to the screen on it.

Thus, information can be transferred to any system. The sensor structure on it is an infrared sensor and it is an imported sensor with caliber and working life up to 15 years.

Main areas of use: Cold storage rooms, Mushroom production facilities, Agricultural production areas (greenhouses, gardens), Fire extinguishing system rooms, Yellowing systems.

GENERAL FEATURES:

  • 1 Carbon dioxide sensor

  • 1 logic input,

  • 2 semi-universal analog outputs

  • 1 Relay output,

  • 2 Modbus RTU RS485 communication ports

  • 2 4 digits 11mm display indicators,

  • 2 4 digit 9mm display indicators,

  • Ac / Dc supply possibility,

  • Adjustable measuring time, filter and response time,

  • Value display in Ppm and%,

  • Operation of analog outputs according to ppm or% value,

  • Warning and guidance in case of sensor failure,

  • 1 relay forwarding feature connected to the sensors,

  • Logic input routing feature, Operation of relays in desired measurement unit and control form,

GENERAL FEATURES:

  • Working in heating / cooling / band on / band off / Timer forms,

  • 1 independent Timer,

  • Working with Timer in alarm situations,

  • Current or Voltage can be output from a single point. It does not require any terminal changes,

  • Current and Voltage output type can be adjusted with jumper,

  • Current and Voltage outputs can be scaled by the user outside of the standard values,

  • Adjustable display options, parameters can be displayed on the desired screen,

  • Automatic point option, the point representation given to the measured values ​​changes automatically according to the measured value,

  • Relay routing can be done according to logic input,

  • Optional voice alert option.

Gaz olcum cıhazı6

HD01-ACN Indicator Carbon Dioxide (CO2) & NTC temperature transmitter. It is used to determine the CO2 and temperature ratios in the environment and to transfer it to the outside world as digital information.

Thanks to the NTC sensors on the device, temperature measurement can be made from 4 points. These sensors can be mounted in metal cases according to the condition of the process and can measure temperature as surface, stud, dipping type. There are analog outputs / relay outputs / RS485 Modbus outputs on our device, which is quite wide in use. Thus, information can be transferred to any system. The sensor structure on it is an infrared sensor and it is an imported sensor with caliber and working life up to 15 years. Thanks to its screen, all data can be observed on the same screen.
Main areas of use: Cold storage rooms, Mushroom production facilities, Agricultural production areas, greenhouses, gardens, Fire extinguishing system rooms, Yellowing systems.

GENERAL FEATURES:

  • 1 Carbon dioxide sensor,

  • 4 NTC sensor inputs,

  • 1 logic input,

  • 1 semi universal analog output,

  • 1 Relay output,

  • 2 Modbus RTU RS485 communication ports,

  • 2 4 digits 11mm display indicators,

  • 2 4 digit 9mm display indicators,

  • Ac / Dc supply possibility,

  • Adjustable measuring time, filter and response time,

  • Value display in Ppm and%,

  • Warning and guidance in case of sensor failure,

  • NTC sensor input and reading feature,

  • 1 relay forwarding feature connected to the sensors,

  • Logic input routing feature,

GENERAL FEATURES:

  • Operation of relays in desired measurement unit and control form,

  • Working in heating / cooling / band on / band off / Timer forms,

  • 1 independent Timer,

  • Working with Timer in alarm situations,

  • Current or Voltage can be output from a single point. It does not require any terminal changes,

  • Current and Voltage output type is selected with jumper,

  • Current and Voltage outputs can be scaled by the user outside of the standard values,

  • Adjustable display options, parameters can be displayed on the desired screen,

  • Automatic point option, the point representation given to the measured values ​​changes automatically according to the measured value,

  • Relay routing can be done according to logic input,

  • Optional voice alert option.

Gaz olcum cıhazı3

It is a TEMPERATURE & HUMIDITY & CARBONDIOXIDE transmitter with HD01-ACT Indicator. It is used to determine the CO2 and Ambient temperature and humidity in the environment and to transfer it to the outside world as digital information.

Thanks to the temperature and humidity sensors on the device, the temperature and humidity values in the environment as well as the carbon dioxide ratio are measured by the device and reflected on the screen as well as information. There are analog outputs / relay outputs / RS485 Modbus outputs on our device, which is quite wide in use.

Thus, information can be transferred to any system. The sensor structure on it is an infrared sensor and it is an imported sensor with caliber and working life up to 15 years.
Main areas of use: Cold storage rooms, Mushroom production facilities, Agricultural production areas, greenhouses, gardens, Fire extinguishing system rooms, Yellowing systems.

GENERAL FEATURES:

  • 2 temperature humidity sensor inputs,

  • 1 Carbon dioxide sensor input,

  • 1 logic input,

  • 1 semi universal analog output,

  • 1 Relay output,

  • 2 Modbus RTU RS485 communication ports,

  • 2 4 digits 11mm display indicators,

  • 2 4 digit 9mm display indicators,

  • Ac / Dc supply possibility,

  • Adjustable measuring unit C&F for temperature sensor,

  • Temperature humidity and dew point measurement feature,

  • Adjustable measuring time, filter and response time,

  • Value display in Ppm and%,

  • Warning and guidance in case of sensor failure,

  • 1 relay forwarding feature connected to the sensors,

  • Logic input routing feature,

GENERAL FEATURES:

  • Operation of relays in desired measurement unit and control form,

  • Working in heating / cooling / band on / band off / Timer forms,

  • 1 independent Timer,

  • Working with Timer in alarm situations,

  • Current or Voltage output can be taken from a single point. It does not require any terminal changes,

  • Current and Voltage output type is selected with jumper,

  • Current and Voltage outputs can be scaled by the user outside of the standard values,

  • Adjustable display options, parameters can be displayed on the desired screen,

  • Automatic point option, the point representation given to the measured values ​​changes automatically according to the measured value,

  • Relay routing can be done according to logic input,

  • Optional voice alert option.

Gaz olcum cıhazı4

HD01-ACTN INDICATOR TEMPERATURE & HUMIDITY & CARBONDIOXIDE & NTC temperature transmitter. It measures the temperature value in the environment thanks to the ambient temperature & humidity sensor on this multi-functional product, the carbon dioxide value in the environment thanks to the CO2 sensor, and the temperature value of the points determined by the 4 NTC sensor inputs on it. These measured values can be opened to the outside world with the help of RS485 Modbus, as well as information can be transferred to a system thanks to the analog output on it. Alarm output can be obtained with the help of the relay on it. With this device, the use of several devices has been prevented and information can be received in one device, parameters can be observed thanks to its screen, and control can be made thanks to its outputs. The values of our device with 4 screens can be determined by selecting from the menu. With its control forms and timer features, it can perform processes on most processes with a single device.
Main areas of use: Cold storage rooms, Mushroom production facilities, Agricultural production areas, greenhouses, gardens, Fire extinguishing system rooms, Yellowing systems.

GENERAL FEATURES:

  • 2 temperature humidity sensor inputs,

  • 4 NTC sensor inputs,

  • 1 Carbon dioxide sensor,

  • 1 logic input,

  • 1 semi universal analog output,

  • 1 Relay output,

  • 2 Modbus RTU RS485 communication ports,

  • 2 4 digits 11mm display indicators,

  • 2 4 digit 9mm display indicators,

  • Ac / Dc supply possibility,

  • Adjustable measuring unit C&F for temperature sensor,

  • Temperature humidity and dew point measurement feature,

  • Adjustable measuring time, filter and response time,

  • Value display in Ppm and%,

  • Warning and guidance in case of sensor failure,

  • NTC sensor input and reading feature, 1 relay forwarding feature connected to the sensors,

GENERAL FEATURES:

  • Operation of relays in desired measurement unit and control form,

  • Working in heating / cooling / band on / band off / Timer forms,

  • 1 independent Timer,

  • Working with Timer in alarm situations,

  • Current or Voltage output can be taken from a single point. It does not require any terminal changes,

  • Current and Voltage output type is selected with jumper,

  • Current and Voltage outputs can be scaled by the user outside of the standard values,

  • Adjustable display options, parameters can be displayed on the desired screen,

  • Automatic point option, the point representation given to the measured values ​​changes automatically according to the measured value,

  • Relay routing can be done according to logic input,

  • Optional voice alert option.

  • Logic input routing feature,

Gaz olcum cıhazı2

HD01-NC is an Indicator Carbon Dioxide (CO2) transmitter. It is used to determine the CO2 rate in the medium and to transfer it to the outside world as digital information.

It gives the CO2 rate of our device as a digital output, as well as showing it to the users thanks to its screen. There are analog outputs / relay outputs / RS485 Modbus outputs on our device, which is quite wide in use.

In this way, information can be transferred to all kinds of systems. The sensor structure on it is an infrared sensor and it is an imported sensor with caliber and working life up to 15 years.

Main areas of use: Cold storage rooms, Mushroom production facilities, Agricultural production areas, greenhouses, gardens, Fire extinguishing system rooms, Yellowing systems.

GENERAL FEATURES:

  • 1 carbon dioxide sensor,

  • 1 logic input,

  • 2 semi-universal analog outputs,

  • 1 Relay output,

  • 2 Modbus RTU RS485 communication ports,

  • Ac / Dc supply possibility,

  • Adjustable measuring time, filter and response time.

  • Value display in Ppm and%,

  • Operation of analog outputs according to ppm or% value,

  • Warning and guidance in case of sensor failure,

  • 1 relay forwarding feature connected to the sensors,

  • Logic input routing feature,

  • Operation of relays in desired measurement unit and control form,

GENERAL FEATURES:

  • Working in heating / cooling / band on / band off / Timer forms,

  • 1 independent Timer,

  • Working with Timer in alarm situations,

  • Current or Voltage output can be taken from a single point. It does not require any terminal changes,

  • Current and Voltage output type is selected with jumper,

  • Current and Voltage outputs can be scaled by the user outside of the standard values,

  • Adjustable display options, parameters can be displayed on the desired screen,

  • Automatic point option, the point representation given to the measured values ​​changes automatically according to the measured value,

  • Relay routing can be done according to logic input,

  • Optional voice alert option.

Gaz olcum cıhazı1

HD01-NCT Indicator CARBONDIOXIDE is a transmitter. It is used to determine the CO2 and Ambient temperature and humidity in the environment and to transfer it to the outside world as digital information.

Thanks to the temperature and humidity sensors on the device, the temperature and humidity values in the environment as well as the carbon dioxide ratio are measured by the device and reflected on the screen as well as information. There are analog outputs / relay outputs / RS485 Modbus outputs on our device, which is quite wide in use.

In this way, information can be transferred to all kinds of systems. The sensor structure on it is an infrared sensor and it is an imported sensor with caliber and working life up to 15 years.
Main areas of use: Cold storage rooms, Mushroom production facilities, Agricultural production areas, greenhouses, gardens, Fire extinguishing system rooms, Yellowing systems.

GENERAL FEATURES:

  • 2 temperature humidity sensor inputs,

  • 1 Carbon dioxide sensor input,

  • 1 logic input,

  • 1 semi universal analog output,

  • 1 Relay output,

  • 2 Modbus RTU RS485 communication ports,

  • Ac / Dc supply possibility,

  • Adjustable measuring unit C&F for temperature sensor,

  • Temperature humidity and dew point measurement feature,

  • Adjustable measuring time, filter and response time,

  • Value display in Ppm and%,

  • Warning and guidance in case of sensor failure,

  • 1 relay forwarding feature connected to the sensors,

  • Logic input routing feature,

GENERAL FEATURES:

  • Operation of relays in desired measurement unit and control form,

  • Working in heating / cooling / band on / band off / Timer forms,

  • 1 independent Timer,

  • Working with Timer in alarm situations,

  • Current or Voltage output can be taken from a single point. It does not require any terminal changes,

  • Current and Voltage output type is selected with jumper,

  • Current and Voltage outputs can be scaled by the user outside of the standard values,

  • Adjustable display options, parameters can be displayed on the desired screen,

  • Automatic point option, the point representation given to the measured values ​​changes automatically according to the measured value,

  • Relay routing can be done according to logic input,

  • Optional voice alert option.

  • Logic input routing feature,

Gaz olcum cıhazı

HD01-NCTN Indicator temperature transmitter. This multifunctional product measures the temperature value in the environment thanks to the ambient temperature & humidity sensor, the carbon dioxide value in the environment thanks to the CO2 sensor, and the temperature value of the points determined by the 4 NTC sensor inputs on it.

These measured values can be opened to the outside world with the help of RS485Modbus, and information can be transferred to a system thanks to the analog output on it. With the help of the relay on it, alarm output can be taken at the values determined. With this device, the use of several devices has been prevented, and both information can be received and controlled thanks to their outputs. With its control forms and timer features, it can perform processes on most processes with a single device.
Main areas of use: Cold storage rooms, Mushroom production facilities, Agricultural production areas, greenhouses, gardens, Fire extinguishing system rooms, Yellowing systems.

GENERAL FEATURES:

  • 2 temperature humidity sensor inputs,

  • 4 NTC sensor inputs,

  • 1 Carbon dioxide sensor,

  • 1 logic input,

  • 1 semi universal analog output,

  • 1 Relay output,

  • 2 Modbus RTU RS485 communication ports,

  • Ac / Dc supply possibility,

  • Adjustable measuring unit C&F for temperature sensor,

  • Temperature humidity and dew point measurement feature,

  • Adjustable measuring time, filter and response time,

  • Value display in Ppm and%,

  • Warning and guidance in case of sensor failure,

  • NTC sensor input and reading feature,

  • 1 relay forwarding feature connected to the sensors,

  • Logic input routing feature,

GENERAL FEATURES:

  • Operation of relays in desired measurement unit and control form,

  • Working in heating / cooling / band on / band off / Timer forms,

  • 1 independent Timer,

  • Working with Timer in alarm situations,

  • Current or Voltage output can be taken from a single point. It does not require any terminal changes,

  • Current and Voltage output type is selected with jumper,

  • Current and Voltage outputs can be scaled by the user outside of the standard values,

  • Adjustable display options, parameters can be displayed on the desired screen,

  • Automatic point option, the point representation given to the measured values ​​changes automatically according to the measured value,

  • Relay routing can be done according to logic input,

  • Optional voice alert option.

  • Optional sensor addition feature

bottom of page